Kyoritsu 8008

Multi-Trans

How to Use
Clamp your instrument around the pick-up coil of the multi-tran.
Then, clamp the transformer jaws of the multi-tran on the conductor, as shown below.
Multiply the reading of your clamp meter by 10 to obtain the current value measured.

Measuring Range 0~3000A AC
Ratio/Range 10 : 1 (input to output)
Accuracy |±2% of input±0.5A
Allowable
Measurement Time
0~1000A (continuous), 1000~1500A (10 minutes max.)
3000A (30 seconds max.)
Conductor Size Ø100mm max.(100 × 150mm)
Frequency Response 50Hz/60Hz
Safety Standard IEC61010-1 CAT.III 300V Pollution Degree 2
Withstand Voltage 3000V AC for 1 minute
Dimensions 317(L) × 150(W) × 30(D)mm
45(L) × 40(W) × 10(D)mm Output coil
Weight 750g approx.
Accessories 9056(Carrying Case)
For use with
following models *
2002PA, 2002R, 2003A(AC only), 2004(AC only), 2006,
2007A(AC only), 2009R(AC only), 2017, 2027, 2031, 2033(AC only),
2037
(AC only), 2040(AC only), 2046R(AC only), 2055(AC only),
2056R(AC only), 2412, 2417, 2431, 2432, 2433, 2433R, 2434,
2608A, 2805, 8113(AC only),

* These Multi-Trans can not be used for leakage current measurement.

Location

Ask about this product