Fluke 1550C Insulation Resistance Tester 5 kV

Category: Insulation Testers

Fluke insulation testers can now conduct the entire range of test voltages specified in IEEE 43-2000 with a best in class, 3 year warranty and CAT IV 600 V safety rating. With measurement storage and PC interface, the 1550C and 1550C are perfect tools for pre-ventative or predictive maintenance programs designed to identify potential equipment failures before they occur.

Specification Fluke 1550C
Insulation resistance Test voltage (dc) Range Accuracy (± reading)
250 V < 200 kΩ
200 kΩ to 5 GΩ
5 GΩ to 50 GΩ
>50 GΩ
unspecified
5 %
20 %
unspecified
500 V < 200 kΩ
200 kΩ to 10 GΩ
10 GΩ to 100 GΩ
>100 GΩ
unspecified
5 %
20 %
unspecified
1000 V < 200 kΩ
200 kΩ to 20 GΩ
20 GΩ to 200 GΩ
>200 GΩ
unspecified
5 %
20 %
unspecified
2500 V < 200 kΩ
200 kΩ to 50 GΩ
50 GΩ to 500 GΩ
>500 GΩ
unspecified
5 %
20 %
unspecified
5000 V < 200 kΩ
200 kΩ to 100 GΩ
100 GΩ to 1 TΩ
>1 TΩ
unspecified
5 %
20 %
unspecified
Bar graph range 0 to 1 TΩ
Insulation test voltage
accuracy
-0 %, +10 % at 1 mA load current
Induced ac mains current
rejection
2 mA maximum
Charging rate for
capacitive load
5 seconds per μF
Discharge rate for
capacitive load
1.5 s/μF
  Range Accuracy
Leakage current 1 nA to 2 mA ± (5 % + 2 nA)
Capacitance 0.01 uF to 15.00 μF ± (15 % rdg + 0.03 μF)
  Range Resolution
Timer 0 to 99 minutes Setting: 1 minute. Indication: 1 second
  Warning range Voltage accuracy
Live circuit warning 30 V to 660 V ac/dc,
50/60 Hz
± (15 % + 2 V)
Display 75 mm x 105 mm
Power 12 V lead-acid rechargeable battery, Yuasa NP2.8-12
Charger Input (AC) 85 V ac 50/60 Hz 20 VA
Dimensions 269 mm x 277 mm x 160 mm (10.6 in x 10.9 in x 6.3 in)
Weight 3.7 kg (8.2 lb)
Temperature (operating) -20 ºC to 50 ºC (-4 ºF to 122 ºF)
Temperature (storage) -20 ºC to 65 ºC (-4 ºF to 149 ºF)
Humidity 80 % to 31 ºC decreasing linearly to 50 % at 50 ºC
Altitude 2000 m
Enclosure sealing IP40
Input overload protection 1000 V ac
Electromagnetic compatibility EN 61326

Location

Ask about this product