Budget DMM Featuring ±0.5% Accuracy
The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The DT4211 is a digital multimeter for the budget-minded, but packed with functions and safety considerations, with ±0.5% DC V accuracy, direct current input, and wide 40 Hz to 500Hz bandwidth.
Extensive measurement functionality
• Large screen for excellent visibility
• No dead batteries during measurement with approx. 800 hours of continuous operating time
• CAT III 600 V, CAT II 1000 V
• Wide operating temperature range of -10°C to 50°C
• 3-year product guarantee, 12-month accuracy guarantee
■ Basic specifications (Accuracy guaranteed for 1 year)
Regarding DMM Accuracy
Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.
DC Voltage | 400.0 mV to 1000 V, 5 ranges, Basic accuracy: ±0.5 % rdg. ±3 dgt. |
---|---|
AC Voltage 40 to 500 Hz | 400.0 mV to 1000 V, 5 ranges, Frequency characteristics: 40 Hz - 500 Hz Basic accuracy: ±1.0 % rdg. ±5 dgt. (Average rectified) |
Resistance | 400.0 Ω to 40.00 MΩ, 6 ranges, Basic accuracy: ±0.5 % rdg. ±2 dgt. |
DC Current | 400.0 μA to 10.00 A, 6 ranges, Basic accuracy: ±1.2 % rdg. ±3 dgt. |
AC Current, 40 to 500 Hz | 400.0 μV to 10.00 A, 6 ranges, Frequency characteristics: 40 Hz - 500 Hz Basic accuracy: ±1.2 % rdg. ±5 dgt. (Average rectified) |
Temperature (use with DT4910) | N/A |
Voltage Detection | N/A |
C (capacitance) | 50.00 nF to 100.0 μF, 5 ranges, Basic accuracy: ±2.0 % rdg. ±5 dgt. |
Frequency | AC V measurement: 5.000 Hz (1 Hz or more) to 5.000 MHz, 7 ranges, Basic accuracy: ±0.1 % rdg. ±3 dgt. Minimum sensitivity voltage: Square wave of 1.5 Vrms |
Continuity Check | Continuity threshold [ON]: 90 Ω ±40 Ω or less (Buzzer sound) |
Diode test | Open terminal voltage: 3.0 V or less, Testing current 0.5 mA |
Environment | Operating temperature: -10 to 50 °C, Storage temperature: -20 to 60 °C |
Other functions | Display value hold, Relative display, Auto-power off, Back light |
Display | 4-digits LCD, max. 4000 counts |
Display refresh rates | 3 times/s |
Power supply | LR6 alkaline batteries ×2, R6P manganese batteries ×2, Continuous use: 800 hours (When using alkaline batteries) |
Dimensions and mass | 91.6 mm (3.61 in)W × 180.6 mm (7.11 in)H× 57.1 mm (2.25 in)D, 388 g (13.7 oz) (including batteries and holster) |
Accessories | Test Lead L9206 ×1, holster (attached) ×1, instruction manual ×1, R6P manganese battery ×2 |