Features:
AC/DC Current up to 1000Amp
Active Power (VAcosθ), Apparent Power (VA), Reactive Power (VA sinθ) and Power Factor (cosθ)
Surge Mode for Inrush Current Measurement
Power, Current, Voltage, Frequency, and Resistance Measurement
Data Hold, Max/Min, and Crest Factor Reading
MAX Clamp Size: 55mm
Description:
Clamp Watt Meter
Specification:
DC VOLTAGE? | ||
Range | 350V, 600V 2 ranges | |
Accuracy | +(1% rdg + 5 digits) | |
Impedance | 5MΩ | |
AC VOLTAGE (45Hz ~ 400Hz) TRUE RMS | ||
Range | 350V, 600V 2 ranges | |
Accuracy | +(1% rdg + 5 digits) | |
Impedance | 5MΩ | |
DC CURRENT | ||
Range | 35A, 350A, 1000A 3 ranges | |
Accuracy | +(1% rdg + 5 digits) | |
AC CURRENT | ||
Range | 35A,350A, 1000A 3 ranges | |
Accuracy | 47Hz ~ 63Hz+(1% rdg + 5 digits) | |
True R.M.S. | Up to 400Hz+(2% rdg + 10 digits) | |
RESISTANCE | ||
Range | 3500Ω | |
Accuracy | +1% | |
CONTINUITY BEEPER | ||
Buzzer sounds if conductance is less than 30Ω | ||
FREQUENCY | ||
Range | 10Hz ~ 1kHz | |
Accuracy | +0.5% | |
PEAK DETECT | ||
Range | All ranges except resistance, audible and frequency test | |
Accuracy | +(3% rdg + 5 digits) Acquisition time 150mS for AC, 10mS for DC |
|
ACTIVE POWER (V x A x Cosθ) | ||
Range | 3.5kW, 35kW, 350kW 3 ranges | |
Accuracy | +(2% rdg + 2 digits) | |
APPARENT POWER (V x A) | ||
3.5kVA, 35kVA, 350kVA+(2% + 5 digits) | ||
REACTIVE POWER (V x A x Sinθ) | ||
3.5kVar, 35kVar, 350kVar+(2% + 5 digits) | ||
POWER FACTOR (Cosθ) | ||
3.5kW, 35kW, 350kW 3 ranges +(3% + 2 digits) |
||
CREST FACTOR | ||
1 ~ 6 range+(3% + 2 digits) | ||
SURGE MODE | ||
ACA ranges to capture and retain current surge long enough for reading | ||
DISPLAY | ||
3 1/2 digits LCD display | ||
POWER SOURCE | ||
AAA x 4 pcs | ||
ACCESSORIES | ||
User manual × 1 Test lead × 1 Alligator clip × 1 Carrying case × 1 |
||
DIMENSIONS & WEIGHT | ||
85(W) × 43(H) × 270(D) mm Approx. 700g |