Features:
* 20,000/2,000 Counts Dual Display
* Test Frequency : 100/120Hz/1/10/100kHz depends on model
* Auto LCR Mode for DUT Measuring
* 0.2% Basic Accuracy
* Measurement Parameter : L,C,R,D,Q,ESR,θ,DCR
* Parallel/Series Testing Mode
* Sorting Mode for Quality Control
* 2Wire or 5Wire Measurement Available
* Data Hold and Zero Mode Supported
* Max and Min (LCR-916 only)
* Auto Range, Auto Backlit
* Low Battery Indication
* Auto Power off
* Data Collection or AC power operation (Optional)
Description:
The LCR-916/915/914 is a smart, convenient and fully-functional dual display handheld LCR meter. The test frequency extends as high as 100 kHz/10kHz, providing greater flexibility to test a wider range of components.The LCR-916/915/914 uses a dual 20,000 /2,000 count display. The 20,000 count display is used for displaying the primary parameters such as capacitance, inductance and resistance as well as DC resistance measurement, and a 2,000 count display is for secondary parameters such as Q, D, ESR and RP measurement. Secondary measurements can also be combined with the primary measurement while the primary measurement is still being taken.
Specification:
LCR-916
|
LCR-915
|
LCR-914
|
|
TEST FREQUENCY
|
|||
|
100Hz/120Hz/1k/10k/100kHz
selectable |
100Hz/120Hz/1k/10kHz
Selectable |
100Hz/120Hz/1kHz
Selectable |
FULL SCALE
|
|||
Main Display
|
20,000/2,000 counts selectable
|
||
Sub Display
|
2,000 counts
|
||
INDUCTANCE
|
|||
Range
|
20uH ~ 20kH depends on the selected test frequency
|
||
Best Accuracy
|
+(0.2% rdg + 2 digits)
|
||
Resolution
|
0.001uH ~ 0.001kH depends on selected range
|
||
CAPACITANCE
|
|||
Range
|
20pF ~ 20mF depends on the selected test frequency
|
||
Best Accuracy
|
+(0.2% rdg + 2 digits)
|
||
Resolution
|
0.001pF ~ 0.001mF depends on selected range
|
||
RESISTANCE
|
|||
Range
|
20Ω ~ 200MΩ depends on the selected test frequency
|
||
Best Accuracy
|
+(0.2% rdg+ 2 digits)
|
||
Resolution
|
0.001Ω ~ 0.01MΩ depends on selected range
|
||
DC RESISTANCE
|
|||
Range
|
200Ω ~ 200MΩ
|
||
Best Accuracy
|
+(0.2% rdg+ 2 digits)
|
||
Resolution
|
0.01Ω ~ 0.01MΩ depends on selected range
|
||
QUALITY FACTOR (Q)
|
|||
Range
|
0.000 ~ 999
|
||
Accuracy
|
2 x (main parameter accuracy)
|
||
Best Resolution
|
0.001
|
||
DISSIPATION FACTOR (D)
|
|||
Range
|
0.000 ~ 999
|
||
Accuracy
|
2 x (main parameter accuracy)
|
||
Best Resolution
|
0.001
|
||
PHASE ANGLE (θ)
|
|||
Range
|
-90° ~ 90°
|
||
Accuracy
|
+(0.2% rdg+ 5 digits)
|
||
Resolution
|
0.1°
|
||
MEASUREMENT CIRCUIT
|
|||
|
Parallel or Series selectable
|
||
AUTO LCR MODE
|
|||
|
Automatically identifies and measures the DUT when the meter is switch on
|
||
SORTING MODE
|
|||
|
+0.1%, +0.2%, +0.25%, +0.5%, +1.0%, +2.0%, +5.0%, +10.0%, +20.0%, +80%/-20% Selectable
|
||
OTHER FUNCTIONS
|
|||
|
Auto range, Auto backlit, Max, Min, Data hold, Zero, Auto power off, 46 segments analogue bar
|
||
DISPLAY
|
|||
|
LCD mono display
|
||
INTERFACE
|
|||
|
USB
|
||
POWER SOURCE
|
|||
|
AA Battery 1.5V x 4 or DC 5V(through AC adapter or USB cable)
|
||
DIMENSIONS & WEIGHT
|
|||
|
95(W) × 207(H) × 52(D) mm, Approx. 630g
|
Accessories:
LCR-916
|
LCR-915
|
LCR-914
|
|
Shorting Cube
|
Standard
|
Standard
|
Standard
|
2Wire Alligator Clip Set
|
Standard
|
Standard
|
Standard
|
Magnetic Hang Kit
|
Standard
|
Standard
|
Opt.04
|
Battery
|
Standard
|
Standard
|
Standard
|
User Manual
|
Standard
|
Standard
|
Standard
|
SMD Test Probe
|
Standard
|
Opt. 02
|
Opt. 03
|
AC Adapter
|
Standard
|
Opt. 02
|
Opt. 03
|
USB Cable
|
Standard
|
Opt. 02
|
Opt. 03
|
PC Software CD
|
Standard
|
Opt. 02
|
N/A
|
4Wire DIP Clip Set
|
Opt. 01
|
Opt. 01
|
Opt. 01
|
Ordering Information:
LCR-916 100kHz Hand-held LCR Meter
LCR-915 10kHz Hand-held LCR Meter
LCR-914 1kHz Hand-held LCR Meter
(*) One year warranty, excluding accessories
Download:
|
Description
|
|
|
|
||||||
1802 K | LCR-916/915/914 User Manual (pdf) | en | VA1 | 2013/12/18 |