TES-Taiwan

TES New

  • Filter
Category: Calibrator

94dB and 114dB Sound Calibration at 1KHz Accurate and Simple to use Fits 1", 1/2" or 1/4" diameter microphone

Test Condition Without Shutting Down Battery. Simultaneously Measure Battery Resistance, Voltage, Current, Temperature. Auto-hold and Auto-data storage. Comparator Function. Rates Conditions as Pass, Warning, or Fail. Memory and Read Function Compact and Lightweight. USB PC Interface Storage Battery Systems Battery Capacity Testers, Check battery condition in seconds, with the battery in service!

Test Condition Without Shutting Down Battery. Simultaneously Measure Battery Resistance, Voltage. Comparator Function. Rates Conditions as Pass, Warning, or Fail. Memory and Read Function Compact and Lightweight. RS232 PC Interface

Category: Anemometer

Fast Response Probe. Air Flow Volume Instant / Avg / 2/3 Vmax Flow Measurement. Velocity m/s, ft/min, knots, km/hr, mph. Data hold & Maximum / Minimum function. Manual data memory and read function (10 x 99 sets). LCD triple display. Auto power off function ON / OFF Time setting. Backlight function ON / OFF Time setting. Snake telescoping probe.

10 Display Easy - to - View LCD Screen. Connectors for 4 Current Sensing Clamps. 1P2W, 1P3W, 3P3W2M & 3P4W Power Measurement. True RMS Sensing. Power KW, KVAR, KVA, PF, θ ,Hz, & Energy KWh, KVARh & KVAh Measurement. Phase sequency indicator function. Backlight display function. Manual Data Memory and Read (99 sets). Data Logging (504KB Memory, 20,000 sets) Programmable Trigger - Points and Start / Stop Time. RS-232 Optical Interface with three phase voltage / current Waveform display and Harmonic analysis. Easy - to - use Push - Button Operation. Light Weight, Portable Design.

Analysis for 3P4W, 3P3W, 1P2W, 1P3W True RMS Value (V 123 and L 123 ) Active Power (W, KW, MW, GW) Apparent and Reactive Power (KVA, KVAR) Power Factor (PF), Phase Angle (Φ) Energy (WH, KWH, KVARH, PFH) Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory Display of 35 Parameters in One Screen(3P4W) Programmable CT (1 to 600) and PT (1 to 3000) Ratios Display of Overlapped Voltage and Current Waveform 2.4M Memory with Programmable Interval (1 to 6000 seconds, 17000 Records for 3P4W System) Output of Waveform, Power Parameters and Harmonics at Command Large Dot Matrix LCD Display with Backlight Average Demand (AD in W, KW, MW) Maximum Demand (MD in W, KW, MW) with Programmable Period Harmonic Analysis to the 99th Order Display of 50 Harmonics in One Screen with Waveform Display of Waveform with Peak Values (1024 Samples/Period) Analysis of Total Harmonic Distortion (%THD-F) Graphic Phasor Diagram with 3 Phase System Parameters Capture 28 Transient Events (Time + Cycles) with Programmable Threshold(%) 3 Phase Voltage Unbalance Ratio (VUR) 3 Phase Voltage Unbalance Factor (d0%,...